The University of Iowa (UIHC)
Department of Pathology
LABORATORY SERVICES HANDBOOK


Cyclobenzaprine (Flexeril)
Order Code: CYCLO
Order Form: A-1a Miscellaneous Request or IPR Req
  Commercial "Mail-out" Laboratory
6240 RCP
356-3527
Specimen
Serum or Plasma
Collection Medium:
Green top tube (Na Heparin)
Alternate
Collection Media:
Red top tube
Minimum:
Preferred minimum:  2.0 mL serum or plasma
Rejection Criteria:
Gel separator tubes.
Delivery Instructions:
Deliver to laboratory immediately after collection.
Analytic Time:
1 week
Reference Range:
Reference Range: 10-30 ng/ml
Critical Value: 100 ng/ml
Comments:
Trough levels are most reproducible.  Indicate specimen type on request 
form and label specimen appropriately.
Methodology:
High Performance Liquid Chromatography with Ultraviolet Detection 
(HPLC-UV)
CPT Code:
82491
 
See Additional Information:
Critical Laboratory Values

Alphabetic main page

Updated: 07/15/2008