C2 Complement Component
Order Code: C2
Epic Lab Code: LAB153
Order Form: A-1a Miscellaneous Request or Epic Req
  Commercial "Mail-out" Laboratory
6240 RCP
356-3527
Specimen:
Serum
Collection Medium:
or
Red top tube Red top tube
Minimum:
Preferred minimum: 1 ml serum (0.5 ml in each of 2 tubes)
Absolute minimum: 0.1 ml serum (0.5 ml in each of 2 tubes)
Reference Range:
By Report
Comments:
Draw blood in red top tube and transfer to Specimen Control (6240 RCP) 
within 1 hour.  Spin, aliquot and freeze serum at -70C.
Methodology:
Radial Immunodiffusion
CPT Code:
86160